APPLICATION CHART FOR EXIDE INSTABRITE BATTERIES |
|||||||
| If Summation of Electrical Load |
Max Inverter Rating | System Voltage | Recommended Battery Capacity for different Backup time | ||||
|---|---|---|---|---|---|---|---|
| 5 Hrs. | 4 Hrs. | 3 Hrs. | 2 Hrs. | 1 Hrs. | |||
| ≤160 Watt | 250 VA | 12V | - | - | - | - | - |
| 161 - 240 Watt | 350 VA | IB1500 INSBRT1500 |
- | - | - | - | |
| 241 - 440 Watt | 650 VA / 700 VA | 2P - IB1500 2P - INSBRT1500 |
- | - | IB1500 INSBRT1500 |
- | |
| 441 - 600 Watt | 850 VA / 900 VA | - | - | 2P - IB1500 2P - INSBRT1500 |
- | - | |
| 601 - 700 Watt | 1050 VA / 1100 VA | 3P - IB1500 3P - INSBRT1500 |
- | 2P - IB1500 2P - INSBRT1500 |
- | IB1500 INSBRT1500 |
|
| 701 - 1000 Watt | 1450 VA / 1500 VA | - | - | - | 2P - IB1500 2P - INSBRT1500 |
- | |
| ≤1000 Watt | 1450 VA / 1500 VA | 24V | 2SX2P - IB1500 2SX2P - INSBRT1500 |
2SX2P - IB1500 2SX2P - INSBRT1500 |
- | - | - |
Note:
1. Cut-off voltage of inverter should be 10.5V (Minimum).
2. There should be a periodic Bench-Charging of the battery after every three months from the date of
installation.
3. S = Series connection; P = Parallel connection; e.g. 2S x 2P = A string containing 2 nos. batteries in
series and 2 nos. such strings in parallel
Consideration of Electrical Load Details
• 1 no. Fan = 80 Watt
• 1 no. Tube light = 40 Watt
TECHNICAL SPECIFICATIONS FOR EXIDE INSTABRITE BATTERIES |
|||||||||||
| Battery Type | Part Number | Ref. C20 Capacity (Ah) | Maximum Overall Dimension (mm) | Nominal Filled Weight (kg) | Electrolyte Volume (litre) | Charging Current (A) | Acid level Indicator | Battery Layout | |||
|---|---|---|---|---|---|---|---|---|---|---|---|
| L | W | H | H (with float) |
||||||||
| IB1500 | FIB0-IB1500 | 150 | 508 | 222 | 257 | 264 | 41.0 | 11.0 | 10.5 | PRESENT | LEFT LAYOUT |
| INSBRT1500 | FIB0-INSBRT1500 | 150 | 508 | 222 | 257 | 264 | 41.5 | 10.6 | 10.5 | PRESENT | LEFT LAYOUT |